  panasonic corporation automation controls business unit industrial.panasonic.com/ac/e he 1 form a (aqv25 ? ) asctb143e 201201-t types *indicate the peak ac and dc values. note: the surface mount terminal indicator ? and the packing style indicator ? or ? are not marked on the device. rating both low on-resistance and good cost-performance achieved. he 1 form a (aqv25 ? ) i/o isolation output rating* pac kage part no. pac king quantity through hole terminal surface-mount terminal load voltage load current tube packing style tape and reel packing style tube tape and reel picked from the 1/2/3-pin side picked from the 4/5/6-pin side ac/dc dual use 1,500v 40 v 500 ma dip6-pin aqv251 aqv251a aqv251ax aqv251az 1 tube contains: 50 pcs. 1 batch contains: 500 pcs. 1,000 pcs. 60 v 400 ma aqv252 aqv252a aqv252ax aqv252az 100 v 350 ma aqv255 aqv255a aqv255ax aqv255az 200 v 250 ma aqv257 aqv257a aqv257ax aqv257az 250 v 200 ma aqv253 AQV253A AQV253Ax AQV253Az 400 v 150 ma aqv254 aqv254a aqv254ax aqv254az 1,000 v 30 ma aqv259 aqv259a aqv259ax aqv259az 1,500 v 20 ma aqv258 aqv258a aqv258ax aqv258az reinforced 5,000v 250 v 200 ma aqv253h aqv253ha aqv253hax aqv253haz 400 v 150 ma aqv254h aqv254ha aqv254hax aqv254haz 600 v 130 ma aqv256h aqv256ha aqv256hax aqv256haz testing (reinforced type, excluding aqv256h) (standard type) mm inch 8.8 6.4 3.9 8.8 6.4 3.6 .346 .252 .154 .346 .252 .142 1 2 3 6 5 4 rohs compliant features 1. wide variation of 40v, 60v, 100v, 200v, 250v, 400v, 600v, 1,000v and 1,500v load voltage 2. low on-resistance of typ. 0.6 ? (aqv251) 3. reinforced insulation type of 5,000v i/o isolation available typical applications ?measuring instruments ?data communication equipment ?telephone equipment ?automatic meter reading device height includes standoff ne w 1. absolute maximum ratings (ambient temperature: 25 c 77 f ) item sym- bol t ype of connec- tion aqv251(a) aqv252(a) aqv255(a) aqv257(a) aqv253(a) aqv254(a) aqv259(a) aqv258(a) aq v253h(a) aqv254h(a) aqv256h(a) remarks input led forward current i f 50 ma led reverse voltage v r 5 v peak forward current i fp 1 a f = 100 hz, duty factor +0.1% pow er dissipation p in 75 mw output load voltage (peak ac) v l 40v 60v 100v 200v 250v 400v 1,000v 1,500v 250v 400v 600v continuous load current i l a 0.5a 0.4a 0.35a 0.25a 0.2a 0.15a 0.03a 0.02a 0.2a 0.15a 0.13a a connection: peak ac, dc b, c connection: dc b 0.7a 0.6a 0.45a 0.35a 0.3a 0.18a 0.04a 0.025a 0.3a 0.18a 0.14a c 1.0a 0.8a 0.70a 0.5a 0.4a 0.25a 0.05a 0.04a 0.4a 0.25a 0.16a peak load current i peak 1.8a 1.5a 1.0a 0.75a 0.6a 0.5a 0.09a 0.06a 0.6a 0.5a 0.4a a connection: 100 ms (1 shot) v l = dc pow er dissipation p out 360 mw total power dissipation p t 410 mw i/o isolation voltage v iso 1,500 v ac 5,000 v ac temperature limits operating t opr ?0 c to +85 c ?0 f to +185 f non-condensing at low temperatures storage t stg ?0 c to +100 c ?0 f to +212 f
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e he 1 form a (aqv25 ? ) asctb143e 201201-t 2. electrical characteristics (ambient temperature: 25 c 77 f ) *turn on/turn off time recommended operating conditions please obey the following conditions to ensure proper device operation and resetting. for dimensions . for s c hematic and wiring di a grams . for cautions f or us e . these products are not designed for automotive use. if you are considering to use these products for automotive applications, please contact your local panasonic corporation technical representative. for more in f ormation . continual dc bias (for aqv258 ?? , a qv259 ?? ) in cases in which a continual dc bias is applied between the input and output, the output-side mos-fet may deteriorate due to the voltage. therefore, please verify operation of the actual design before using. an example of a circuit that might undergo mos-fet deterioration due to voltage is given below. item sym- bol t ype of con- nection a qv251(a) aqv252(a) aqv255(a) aqv257(a) aqv253(a) aqv254(a) aqv259(a) aqv258(a) aq v253h(a) aqv254h(a) aqv256h(a) condition input led operate current typical i fon 0.9 ma 1.4 ma i l = max. maximum 3 ma led turn off current minimum i foff 0.4 ma i l = max. typical 0.8 ma 1.3 ma led dropout voltage typical v f 1.25 v (1.14 v at i f = 5 ma) i f = 50 ma maximum 1.5 v output on resistance typical r on a 0.6 ? 0.74 ? 1.8 ? 2.6 ? 5.5 ? 12.4 ? 85 ? 345 ? 5.5 ? 12.4 ? 20 ? i f = 5 ma i l = max. within 1 s on time maximum 1 ? 1.4 ? 2.5 ? 4 ? 8 ? 16 ? 200 ? 500 ? 8 ? 16 ? 30 ? typical r on b 0.3 ? 0.37 ? 0.9 ? 1.4 ? 2.7 ? 6.2 ? 60 ? 345 ? 2.7 ? 6.2 ? 15 ? i f = 5 ma i l = max. within 1 s on time maximum 0.5 ? 0.7 ? 1.25 ? 2 ? 4 ? 8 ? 100 ? 500 ? 4 ? 8 ? 20 ? typical r on c 0.15 ? 0.18 ? 0.45 ? 0.7 ? 1.4 ? 3.1 ? 30 ? 160 ? 1.4 ? 3.1 ? 7.5 ? i f = 5 ma i l = max. within 1 s on time maximum 0.25 ? 0.35 ? 0.63 ? 1 ? 2 ? 4 ? 50 ? 250 ? 2 ? 4 ? 10 ? off state leakage current maximum i leak ? a 10 a1 a i f = 0 ma v l = max. tr ansfer characteristics tu rn on time* typical t on 1.7 ms 1.4 ms 0.9 ms 1.5 ms 0.8 ms 0.6 ms 0.35 ms 2.4 ms 1.8 ms 1.2 ms i f = 5 ma i l = max. maximum 3 ms 2 ms 3 ms 2 ms 1 ms 4 ms 3ms tu rn off time* typical t off 0.07 ms 0.09 ms 0.1 ms 0.06 ms 0.05 ms 0.04 ms 0.06 ms 0.05 ms 0.06 ms i f = 5 ma i l = max. maximum 0.2 ms i/o capacitance typical c iso 1.3 pf f = 1 mhz v b = 0 v maximum 3 pf initial i/o isolation resistance minimum r iso 1,000 m ? 500 v dc item symbol recommended value unit input led current i f standard type: 5 reinforced insulation type: 5 to 10 ma ton input output 10% 90% toff
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e he 1 form a (aqv25 ? ) asctb143e 201201-t reference data 1.-(1) load current vs. ambient temperature characteristics allowable ambient temperature: ?0 c to +85 c ?0 f to +185 f ; type of connection: a 1.-(2) load current vs. ambient temperature characteristics allowable ambient temperature: ?0 c to +85 c ?0 f to +185 f ; type of connection: a 2.-(1) on resistance vs. ambient temperature characteristics measured portion: between terminals 4 and 6; led current: 5 ma; continuous load current: max. (dc) 0 0.2 0.4 0.6 0.1 0.3 0.5 aqv257 aqv253(h) aqv254(h) aqv256h aqv251 aqv252 aqv255 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 100 load current, a aqv259 aqv258 ambient temperature, c load current, ma 0 20 30 50 10 40 -40 -20 0 2 0 4 0 6 0 8085 100 0 0.5 2.0 2.5 1.0 1.5 aqv255 4.0 3.5 4.5 5.0 3.0 aqv252 aqv251 aqv257 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 on resistance, ? 2.-(2) on resistance vs. ambient temperature characteristics measured portion: between terminals 4 and 6; led current: 5 ma; continuous load current: max. (dc) 2.-(3) on resistance vs. ambient temperature characteristics measured portion: between terminals 4 and 6; led current: 5 ma; continuous load current: 30 ma (dc) 3.-(1) turn on time vs. ambient temperature characteristics led current: 5 ma; load voltage: max. (dc); continuous load current: max. (dc) 0 15 10 20 25 5 35 40 30 aqv253(h) aqv254(h) aqv256h ambient temperature, c on resistance, ? -40 -20 0 2 0 4 0 6 0 8085 0 100 200 300 aqv258 400 500 aqv259 ambient temperature, c on resistance, ? -40 -20 0 2 0 4 0 6 0 8085 0 2 4 1 3 aqv251 aqv252 aqv257 aqv253 aqv254 aqv255 aqv259 aqv258 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 tu r n on time, ms 3.-(2) turn on time vs. ambient temperature characteristics led current: 5 ma; load voltage: max. (dc); continuous load current: max. (dc) 4.-(1) turn off time vs. ambient temperature characteristics led current: 5 ma; load voltage: max. (dc); continuous load current: max. (dc) 4.-(2) turn off time vs. ambient temperature characteristics sample: aqv253h, aqv254h, aqv256h led current: 5 ma; load voltage: max. (dc); continuous load current: max. (dc) 0 2 5 1 3 aqv253h aqv254h aqv256h 4 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 tu r n on time, ms 0 0.2 0.3 0.4 0.1 aqv251,aqv252,aqv255 aqv253,aqv257 aqv259,aqv258 aqv254 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 tu rn off time, ms 0 0.2 0.3 0.5 0.1 0.4 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 tu rn off time, ms 5.-(1) led operate current vs. ambient temperature characteristics sample: aqv251, aqv252, aqv253, aqv254, aqv255, aqv258, aqv259; load voltage: max. (dc); continuous load current: max. (dc) 5.-(2) led operate current vs. ambient temperature characteristics sample: aqv253h, aqv254h, aqv256h; load voltage: max. (dc); continuous load current: max. (dc) 6.-(1) led turn off current vs. ambient temperature characteristics sample: aqv251, aqv252, aqv253, aqv254, aqv255, aqv258, aqv259; load voltage: max. (dc); continuous load current: max. (dc) 0 2 3 4 1 ambient temperature, c led operate current, ma -40 -20 0 2 0 4 0 6 0 8085 0 2 3 5 1 4 ambient temperature, c led operate current, ma -40 -20 0 2 0 4 0 6 0 8085 0 2 3 1 4 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 led turn off current, ma
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e he 1 form a (aqv25 ? ) asctb143e 201201-t 6.-(2) led turn off current vs. ambient temperature characteristics sample: aqv253h, aqv254h, aqv256h; load voltage: max. (dc); continuous load current: max. (dc) 7. led dropout voltage vs. ambient temperature characteristics led current: 5 to 50 ma 8.-(1) current vs. voltage characteristics of output at mos portion measured portion: between terminals 4 and 6; ambient temperature: 25 c 77 f 0 2 3 5 1 4 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 led turn off current, ma 0 1.0 1.1 1.2 1.3 1.4 50ma 30ma 20ma 10ma 5ma 1.5 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 100 led dropout voltage, v aqv251 aqv252 aqv255 aqv257 aqv253(h) aqv254(h) aqv256h 3.0 2.52.01.51.00.5 -0.5-1.0-1.5-2.0-2.5-3.0 -0.1 -0.2 -0.3 -0.4 -0.5 -0.6 0.6 0.5 0.4 0.3 0.2 0.1 v oltage, v current, a 8.-(2) current vs. voltage characteristics of output at mos portion measured portion: between terminals 4 and 6; ambient temperature: 25 c 77 f 9-(1). off state leakage current vs. load voltage characteristics sample: aqv259; measured portion: between terminals 4 and 6; ambient temperature: 25 c 77 f 9-(2). off state leakage current vs. load voltage characteristics measured portion: between terminals 4 and 6; ambient temperature: 25 c 77 f aqv259 aqv258 40 30 20 10 v oltage, v current, ma -40 -30 -20 -10 8642 -8 -6 -4 -2 100806040200 10 ? 10 ? 10 ? 10 ?2 load voltage, v off state leakage current, a aqv254h aqv256h load voltage, v off state leakage current, a 100806040200 10 ? 10 ? 10 ? 10 ?2 10-(1). turn on time vs. led forward current characteristics measured portion: between terminals 4 and 6; load voltage: max. (dc); continuous load current: max. (dc); ambient temperature: 25 c 77 f 10-(2). turn on time vs. led forward current characteristics measured portion: between terminals 4 and 6; load voltage: max. (dc); continuous load current: max. (dc); ambient temperature: 25 c 77 f 11-(1). turn off time vs. led forward current characteristics measured portion: between terminals 4 and 6; load voltage: max. (dc); continuous load current: max. (dc); ambient temperature: 25 c 77 f 0 0.5 1.0 1.5 2.0 3.0 aqv253,aqv254,aqv257,aqv255 2.5 aqv252 aqv251 aqv259 aqv258 led current, ma tu r n on time, ms 6050403020100 0 2 4 6 8 12 10 aq v253h aqv256h aqv254h led current, ma tu r n on time, ms 6050403020100 0 0.02 0.04 0.08 0.06 0.12 aqv251,aqv252,aqv255 0.10 aqv253,aqv257 aqv254 aqv259,aqv258 led current, ma 50403020100 tu rn off time, ms 11-(2). turn off time vs. led forward current characteristics measured portion: between terminals 4 and 6; load voltage: max. (dc); continuous load current: max. (dc); ambient temperature: 25 c 77 f 12.-(1) output capacitance vs. applied voltage characteristics measured portion: between terminals 4 and 6; frequency: 1 mhz; ambient temperature: 25 c 77 f 12.-(2) output capacitance vs. applied voltage characteristics sample: aqv259; measured portion: between terminals 4 and 6; frequency: 1 mhz; ambient temperature: 25 c 77 f aqv253h,254h,aqv256h tu rn off time, ms 0 0.02 0.04 0.08 0.06 0.12 0.10 led current, ma 50403020100 0 100 200 600 300 400 500 6050403020100 output capacitance, pf applied voltage, v aqv251,aqv252 aqv253(h),aqv254(h),aqv257 0 20 40 120 60 80 100 aqv259 aqv256h 6050403020100 output capacitance, pf applied voltage, v


▲Up To Search▲   

 
Price & Availability of AQV253A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X